Features
Specifications
Model Number: QMD20/90-XL-14
Fire Extinguishing Agent Composition: Nitrogen Fire Fighting System
Working Pressure At 20℃: 20MPa
Maximum Working Pressure At 50℃: 237.5kg/M³
Activation Method: Automatic, Pneumatic, Manual, Mechanical Emergency Operation
Fire Extinguishing Mode: Enclosed Flooding
Applications: Airport Air Traffic Control Center
Highlight:

IG100 automatic fire extinguisher system

,

20MPa automatic fire extinguisher system

,

Enclosed Flooding fire suppression agent

Basic Infomation
Place of Origin: China
Brand Name: XL
Certification: SGS,TÜV,ISO9001,ISO14001,CNAS,CAL
Model Number: QMD20/90-XL-14
Payment & Shipping Terms
Packaging Details: Plywood Outer Box With Bubble Bag Or Paper
Delivery Time: 10 Days, Subject To Quantity Negotiation
Payment Terms: L/C,D/P,T/T,Western Union,Paypal,Credit Card
Supply Ability: 65000 Sets Per Week
Product Description

IG100 Clean Agent Fire Suppression System For Airport Air Traffic Control Center Automatic Fire Extinguisher

 

 

Technical parameter:

 

No. Product IG100 Nitrogen Fire Fighting System
1 Capacity 70ltr,80ltr,90ltr
2 Working Pressure 20MPa 30MPa
3 Device Model QMH20/90 QMH30/90
4 Model Number QMD20/90-XL-14
5 Discharge Time ≤60S
6 Working pressure and temperature 0~50℃
7 Driving Bottle Group Pressure 23.5MPa
8 Maximum Working Pressure at 50℃ 237.5kg/M³
9 Fire Extinguishing Method Full Flooding
10 Activation Method Automatic, Pneumatic, Manual, Mechanical Emergency Operation
11 Applications Airport Air Traffic Control Center

 
 

Description:

 

Engineered to meet the stringent safety demands of airport air traffic control centers, the IG100 Clean Agent Fire Suppression System combines advanced inert gas technology with globally recognized certifications, setting a benchmark for reliability and performance. As a product of a manufacturing system certified by both SGS factory inspection and TÜV Rheinland audit, alongside ISO 9001 (Quality Management) and ISO 14001 (Environmental Management) compliance, this system delivers uncompromised fire protection tailored for critical aviation environments.


1. Non-Destructive Inert Gas Suppression
The system utilizes nitrogen as its clean agent, ensuring zero residue on sensitive avionics, radar systems, and communication equipment—critical for maintaining signal integrity in control centers. Unlike water or 干粉 (dry powder) systems that cause corrosion or data loss, the IG100 clean agent fire suppression system extinguishes fires by reducing oxygen concentration to 12–15%, a level that suffocates flames without damaging delicate electronics or leaving conductive residues.


2. Electrical Safety for Mission-Critical Systems
Airport control centers rely on 24/7 operation of high-voltage switchgear, radar transmitters, and digital communication networks. The IG100 system’s non-conductive nitrogen agent safely suppresses Class C (electrical) fires in energized systems, eliminating risks of short circuits or arc flashes that could disrupt air traffic management. This feature is vital for protecting systems like ADS-B (Automatic Dependent Surveillance-Broadcast) and ATCRBS (Air Traffic Control Radar Beacon System), where even a momentary failure poses catastrophic risks.


3. Environmental Compliance and Sustainability
Aligned with global aviation’s ESG goals, the IG100 clean agent fire suppression system features zero ODP (ozone depletion potential) and zero GWP (global warming potential), complying with FAA (Federal Aviation Administration) and ICAO (International Civil Aviation Organization) environmental standards. The nitrogen-based formula is 100% recyclable and eliminates hazardous waste disposal, reflecting our commitment to sustainable aviation practices certified by ISO 14001.

 

 
Application:
 

The nerve center of airport operations, control towers house radar displays, communication radios, and flight data processing systems:
Primary Control Rooms: The system protects multi-screen radar consoles and voice communication networks from electrical faults or overheating, ensuring no disruption to pilot communications or airspace monitoring.
Backup Control Suites: In redundant systems, the residue-free agent preserves the integrity of standby equipment, enabling seamless transition to backup modes during fire events.
GNSS Signal Rooms: Non-conductive nitrogen safeguards global navigation satellite system receivers, preventing signal degradation caused by traditional fire suppressants.


1. Communication and Data Centers
Airport control centers rely on data hubs managing flight schedules, baggage systems, and security feeds:
Server Farms: The IG100 clean agent fire suppression system protects virtual flight planning servers and real-time data storage arrays, ensuring zero data loss during fire suppression—a must for complying with IATA data integrity standards.
VoIP and Radio Systems: Eliminates risks to voice-over-IP switches and VHF/UHF radios, preserving clear communication channels between controllers, pilots, and ground crews.


2. UPS and Generator Rooms
In backup power facilities supporting control center operations:
Battery Storage Areas: Mitigates thermal runaway in lithium-ion UPS batteries, a growing risk in 24/7 aviation environments. The system’s prolonged oxygen reduction (maintaining ≤12% O₂ for 30+ minutes) prevents re-ignition in battery clusters.
Diesel Generator Halls: Safely suppresses fuel leaks or electrical faults in generators, ensuring uninterrupted power supply during grid outages.

 
 
Company profile:
 
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd., established in 2017 with a registered capital of RMB 10 million, is a leading provider of advanced fire safety solutions headquartered in Dongzhou Industrial Park, Xintang Town, Zengcheng District, Guangzhou. Committed to innovation and reliability, the company specializes in state-of-the-art clean gas automatic fire extinguishing systems, including FM200(HFC-227ea),Novec1230,IG541 and IG100 systems, complemented by sophisticated gas fire alarm control panels.These products are widely adopted across diverse sectors, such as municipal infrastructure, power plants, telecommunications, healthcare facilities, and construction projects, thanks to their efficiency, safety, and environmental sustainability.
 
Supported by over 30 patents and a team with more than eight years of collective expertise in fire protection engineering, Xinlin Fire offers comprehensive services spanning system design, engineering, and seamless project execution. Operating from a modern 2398 - square - meter facility, Xinlin Fire integrates automated production lines and cutting - edge testing equipment to ensure consistent, high - quality output.
The company's production system has passed the dual certifications of the internationally authoritative SGS factory inspection certification and the German TÜV Rheinland factory inspection. At the same time, it has obtained ISO 9001 (Quality Management System), ISO 14001 (Environmental Management System), and ISO 45001 (Occupational Health and Safety Management System). Ensure that every link of the product from production to delivery complies with international standards. In addition, we also provide Chemical Data Sheets (MSDS) to comprehensively ensure the compliance and safety of product transportation, storage and use. Choosing us means choosing professionalism and trust.
 
IG100 automatic fire extinguisher system For Airport Air Traffic Control Center 0

 

Frequently Asked Questions:

 
Q1: Are you a manufacturer or a trading company?
A1: We are a professional manufacturer specializing in gas fire suppression systems.

Q2: Can you give me a sample order?
A2: Yes, of course you can. We welcome you to order samples to test and check the product quality. Provide mixed samples.
Q3: Do you offer OEM products?
A3: Yes, we welcome your own designs and drawings.
Q4: Where is your factory located?
A4: Our factory is situated in the East Lake Industrial Park of XinTang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.
Q5: How can I get to your factory?
A5: Due to convenient transportation, you can reach us by taxi or by subway. If taking the subway, please take Line 13 to Shacun Station. Before disembarking, kindly inform us in advance, and we will arrange for a comfortable business van to pick you up from there.
 
 

Recommended Products
Get in touch with us
Tel : 18933963312
Fax : 86-020-22946890
Characters Remaining(20/3000)